Cooper Lighting Indoor Furnishings UX NEMA 4X User Manual

®
COOPER LIGHTING - SURE-LITES  
DESCRIPTION  
DIMENSIONS  
-49°F to +140°F  
The Sure-Lites UX NEMA 4X Exit combines the strength and  
durability of die cast aluminum with architecturally pleasing  
aesthetics. Designed for the most severe environments, the UX  
exit will provide maximum performance against rain, moisture,  
cold, corrosives and dust. Universal configurations (single and  
double face) and universal mounting provide the ease of one  
product specifying for any job. Additional designed-in features  
such as LED technology provide the customer with a long life,  
low maintenance, dependable exit sign in those conditions  
when reliability is crucial. The injection molded, clear,  
5.50  
UX SERIES  
polycarbonate shield not only provides protection against  
®
moisture and rain, but vandalism as well. (4) Torx head  
tamperproof screws with center-pin reject provide additional  
vandal-proof security. The unique design and features make the  
UX Exit compatible in food processing facilities, outdoor  
parking garages, walk-in freezers and other indoor/outdoor  
severe environments. The UX Exit is approved for ambient  
environments rated from -45°C (-49°F) up to +60°C (+140°F).  
Ultimate Exit  
AC Only  
Self-Powered  
13.72  
EXIT LIGHTING  
5.50  
NEMA 4X Listed  
Self-Diagnostics  
The self-diagnostic unit will automatically  
perform all tests required by UL924 and  
NFPA 101. The system indicates the status of  
the unit at all times using the LED indicator  
near the test switch on the side of the unit. A  
90 minute battery power (emergency mode)  
simulation test will occur randomly once  
every six months.  
Operating temperature  
-45°C (-49°F) to 60°C (+140°F)  
0.88  
Dual voltage input 120/277  
VAC, 60Hz Isolation  
Transformer  
9.21  
8.35  
Die Cast aluminum housing  
Powder coat finish  
LED Lamping  
A 30 second battery power simulation test  
will occur every 30 days.  
2.13  
3.80  
Exit can be universally  
mounted ceiling, wall or end  
Universal pattern knockouts  
on rear of single face housing  
for direct mounting to junction  
box  
ORDERING INFORMATION  
SAMPLE NUMBER: UX61R  
Pendant Mount  
Watchguard EMS  
Self-diagnostic system  
Laser Testing  
Factory  
Options  
95=AC Only  
Fire  
Housing  
Finishes  
Blank=Silver  
BK=Black  
WH=White  
Options  
Accessories (Order Separately)  
Family  
UX=Nema  
4X Exit  
2C=Two Circuit  
Operation,  
FTBR  
HAZ=Hazardous  
Locations  
(Class 1,  
UXUK=Converts single face exit to  
Premium Nickel Cadmium  
batteries  
double face exit. Contains (1) red lens,  
(1) green lens, (1) Standard Silver Exit  
Stencil, (1) Vandal Shield &  
Alarm  
T6 HAZ lamp rating  
Series  
6=AC Only, LED  
7=Self-powered  
Interface  
90=DC Only  
Fire  
Alarm  
Interface  
Tamperproof Screws  
SD=Self-  
Diagnostics  
(Standard  
for UX7  
UXUKWH=Converts single face exit to  
double face exit. Contains (1) red lens,  
(1) green lens, (1) White Exit Stencil,  
(1) Vandal Shield & Tamperproof  
Screws  
IP66, Ingress Protection from  
IEC (International Electrical  
Commission)  
Division 2,  
Groups A,  
B, C, D)  
Face Options  
0=Universal (single and  
double face)(1)  
1=Single  
(Both can  
be ordered)  
only)  
UL844, Hazardous Locations  
(Class 1, Division 2, Groups A,  
B, C, D) with “HAZ” option  
Letter Colors  
R=Red  
G=Green  
UXUKBK=Converts single face exit to  
double face exit. Contains (1) red lens,  
(1) green lens, (1) Black Exit Stencil,  
(1) Vandal Shield & Tamperproof  
Screws  
UL FTBR Listed when specified  
with the “2C” option  
UXPKA=Pendant Kit Adapter (fitting  
adapts exit to 1/2" NPT threaded  
pendant "supplied by others")  
Suitable for Floor Proximity  
Installation, UL Listed, ADA  
(American Disabilities Act)  
VRSD=Vandal Resistant Screwdriver  
LASER=Key Chain, Laser pointer (UX7  
only), (activated at 30 ft.)  
NSF National Sanitation  
Foundation / Splash Zone  
(for Food Processing)  
Energy Data — AC Only Exits  
Cleanrooms Class 10,000  
Input Power:  
Input Current (Max.):  
120V 277V  
LED Exits  
.07A  
.08A  
Power Factor:  
T.H.D.:  
UL 924, UL 924 Wet Location  
(Suitable for wet and damp  
locations), NEC/OSHA, Life  
Safety NFPA 101, Meets most  
state and local codes  
120V 277V  
120V 277V  
120V 277V  
LED Exits -Red Letters  
LED Exits -Green Letters  
2.7W 3.2W  
2.3W 3.0W  
.04A  
.03A  
> .30 > .39  
> .26 > .36  
< 56% < 69%  
< 54% < 67%  
Patents Pending  
SPLASH ZONE  
(1) Contains one single face exit and one UXUK.  
662 COOPER LIGHTING  
 

Coleman Stove 5453 User Manual
Cornelius Beverage Dispenser 6 Flavor User Manual
Cortelco Telephone 8782 User Manual
Craftsman Lawn Mower 917387258 User Manual
Dell Scanner MH941 User Manual
Dixon Lawn Mower ZTR 5425 User Manual
D Link Network Router DWL 810 User Manual
Duracell Battery Charger PX28L User Manual
Electro Voice Portable Speaker MB3 User Manual
Electro Voice Speaker EVX 150A User Manual