Linear Pressure Washer XR 16 User Manual

WARNING: THIS  
PRODUCT SHOULD NOT  
BE USED IN LIFE  
1. PRODUCT DESCRIPTION  
2. SYSTEM OVERVIEW  
3. DISPLAYED CONDITIONS  
Linear’s Xtended Range FM receivers and transmitters are designed for use in various  
wireless remote control applications. When the Model XR-16 receiver detects a signal  
from its companion transmitters, it will verify the digital code, activate the correct output  
channel, and trigger the remote device connected to the receiver.  
XR-16  
XTENDED RANGE  
SIXTEEN CHANNEL  
SUPERVISED  
STATIONARY  
RECEIVER  
TRANSMITTER CONDITION  
SAFETY APPLICATIONS.  
EXAMPLE  
TRANSMITTERS  
FCC Rules allow  
unlicensed high-power  
transmissions at or near  
the operating frequency  
of this product which  
may interfere with, or  
even disable, normal  
operation of this radio  
device.  
The XR-16 receiver has full supervision capabilities. If the “status” option for a channel  
is selected, the receiver expects hourly status signals from that channel’s transmitter.  
If these signals cease, the receiver will indicate trouble by activating its status output  
after four hours. Contact supervision allows the receiver’s outputs to follow the  
transmitter’s inputs, each output staying activated as long as each transmitter input is  
activated. Alternately, an “auto-restore” option can be selected in the transmitter,  
causing a momentary receiver output each time any transmitter input is activated. If  
the transmitter sends a low battery signal, the receiver’s low battery output will activate.  
SIGNAL  
INDICATOR  
POWER  
INDICATOR  
CONDITIONS FOR ALL TRANSMITTERS  
ROTATE ON THE DISPLAY  
Power for the XR-16 receiver can come from an external 12 VDC power supply (Linear  
Model T-1224DC) or from a 12-volt battery. A diode protects the unit from reverse  
power polarity. The XR-16 draws about 50 mA standby, and about 350 mA when all  
outputs are active. The alarm, low battery and status outputs are solid state and are  
capable of switching up to 100 mA @ 24 VDC to ground (programmable as N/O or  
N/C). The receiver’s relay can activate with all signals, or just alarm signals. It provides  
isolated N/O and N/C relay contacts capable of switching a maximum of 1 Amp @  
24 VDC.  
TRANSMITTER ALARM  
TRANSMITTERS WILL CAUSE THIS CONDITION WHEN THEY SEND A  
VIOLATION SIGNAL. THE CONDITION WILL REMAIN UNTIL A RESTORE  
SIGNAL IS SENT, UNLESS THE TRANSMITTER IS SET AS "AUTO  
RESTORE". THE TRANSMITTER'S CHANNEL OUTPUT WILL BE FAULTED  
AS LONG AS THIS CONDITION IS DISPLAYED.  
For Use With  
MODEL  
XT-1  
MODEL  
XT-4  
Linear’s XR Series  
Xtended Range  
Transmitters  
TRANSMITTER LOW BATTERY  
ANY TRANSMITTER SENDING A LOW BATTERY SIGNAL WILL CAUSE THIS  
CONDITION. DISPLAY WILL REMAIN UNTIL A SIGNAL OCCURS FROM THE  
SAME TRANSMITTER WITH A GOOD BATTERY.  
Two antennas (sold separately) are available for the XR-16. The Model ANT-1A is an  
8-inch “rubber duck” antenna for short range applications (less than 1 mile). The ANT-1  
requires a Model CON-180A connector to mate the antenna to the receiver. The Model  
ANT-2 is a 3-foot whip antenna for use in long range or difficult installations where more  
range from the XR-16 is required. A common 9-foot 1/4 wave CB whip antenna can  
also be used with the XR-16 for maximum range.  
AN UNLIMITED NUMBER  
OF TRANSMITTERS CAN  
BE USED WITH THE XR-16  
TRANSMITTER STATUS ALERT  
EACH RECEIVER CHANNEL CAN BE SET AS SUPERVISED OR NON-  
SUPERVISED. IF THE RECEIVER DOES NOT RECEIVE STATUS SIGNALS  
FROM A TRANSMITTER PROGRAMMED TO A SUPERVISED CHANNEL  
FOR FOUR HOURS, THIS CONDITION WILL BE DISPLAYED. DISPLAY WILL  
CLEAR THE NEXT TIME A SIGNAL IS RECEIVED FROM THE  
TRANSMITTER.  
Installation  
Instructions  
Two 8-position switches set the unit’s system code. This code must be matched in the  
XR-16’s transmitters. There are 65,536 different system codes possible. The two  
8-position option switches select the status supervision option for each of the  
16 channels.  
The receiver is housed in a metal enclosure with an SO-239 antenna connector. Three  
displays are visible through a window on the case. The left two displays show the  
channel number, the right display shows the condition. The display scrolls through all  
the channel numbers with a condition. The right decimal point lights when the receiver  
has power. During reception, the center decimal point lights. Two internal test points  
are provided for signal strength and audio monitoring.  
16 CHANNEL  
OUTPUT  
(760) 438-7000 • FAX (760) 438-7043  
USA & Canada (800) 421-1587 & (800) 392-0123  
Toll Free FAX (800) 468-1340  
DASHES WILL MOVE ACROSS THE  
DISPLAY WHILE THE RECEIVER IS IDLE  
XR-16 RECEIVER  
CONTROL PANEL  
4. COMPONENT LOCATIONS  
5. MOUNT RECEIVER  
6. CONNECT ANTENNA  
7. TERMINAL BLOCK DETAILS  
XR-16 TERMINALS  
POWER INPUT  
7"  
USE ANT-1A ANTENNA FOR  
SHORT RANGE (LESS THAN  
1 MILE) APPLICATIONS  
SYSTEM CODE  
SWITCHES "A" & "B"  
ANT-1A  
ANTENNA  
GND  
+12 VDC  
COM  
FOR CONNECTION TO A REGULATED DC POWER SOURCE.  
THE POWER INPUT CAN BE FROM 11-16 VDC ONLY.  
RELAY OUTPUT  
STATUS OPTION  
SWITCHES 1-16  
MOUNTING  
PATTERN  
DRY CONTACTS, FORM C, 1 AMP @ 24 VDC MAXIMUM  
RATING. JUMPER SELECTABLE TO ACTIVATE AS LONG AS  
ANY OUTPUT IS ACTIVE, OR AS LONG AS ANY CHANNEL  
OUTPUT IS ACTIVE.  
5-1/8"  
5-1/8"  
N/C  
CON-180A  
STRAIGHT  
CONNECTOR  
N/O  
TRANSMITTER  
CHANNEL  
NUMBER  
GND  
STATUS OUTPUT  
ACTIVATES WHEN ANY CHANNEL PROGRAMMED TO  
EXPECT STATUS TRANSMISSIONS DOES NOT RECEIVE ANY  
STATUS SIGNALS FOR FOUR HOURS. REMAINS ACTIVE  
UNTIL SIGNALS ARE RECEIVED AND ALL STATUS  
STS ALM  
LOW BAT  
GND  
ANTENNA  
CONNECTOR  
USE SCREWS AND ANCHORS TO  
MOUNT THE RECEIVER  
TRANSMITTER  
CONDITION  
INDICATIONS ("S" ON CONDITION DISPLAY) ARE CLEARED.  
USE 3-FOOT LONG ANT-2  
ANTENNA FOR LONGER  
RANGE APPLICATIONS OR  
DIFFICULT INSTALLATIONS  
CH16  
CH15  
CH14  
CH13  
GND  
LOW BATTERY OUTPUT  
ACTIVATES WHEN ANY TRANSMITTER SENDS A LOW  
BATTERY SIGNAL. REMAINS ACTIVE UNTIL A GOOD  
BATTERY SIGNAL IS RECEIVED AND ALL LOW BATTERY  
INDICATIONS ("L" ON CONDITION DISPLAY) ARE CLEARED.  
RECEIVER CHANNEL OUTPUTS  
CH12  
CH11  
CH10  
CH9  
EACH OUTPUT ACTIVATES WHEN ANY TRANSMITTER  
PROGRAMMED FOR THAT CHANNEL IS IN THE VIOLATED  
(ALARM) CONDITION. REMAINS ACTIVE UNTIL ALL  
TRANSMITTERS PROGRAMMED TO THAT CHANNEL ARE  
RESTORED AND ALL ALARM INDICATIONS ("A" ON  
CONDITION DISPLAY) ARE CLEARED.  
MOUNT ANTENNA AS HIGH AS POSSIBLE  
(A METAL MOUNTING POLE IS  
RECOMMENDED)  
TEST POINTS  
SIGNAL  
LEVEL  
ATTACH CASE WITH  
TWO SCREWS IN  
KEYHOLE SLOTS,  
THEN SECURE CASE  
WITH TWO BOTTOM  
SCREWS  
AUDIO  
IF THE TRANSMITTER IS PROGRAMMED FOR AUTO-  
RESTORE, THE OUTPUT WILL BE MOMENTARY,  
ACTIVATING FOR ONLY TWO SECONDS.  
GND  
OUTPUT  
CH8  
AN 18-FOOT RG-58 CABLE IS SUPPLIED  
WITH THE ANT-2 KIT. UP TO 50 FEET OF  
RG-58 CAN BE USED. USE RG-8 FOR UP  
TO 100-FOOT CABLE RUNS.  
GROUND  
CH7  
NOTES:  
CH6  
1. OUTPUTS CAN CONNECT TO ZONE INPUTS ON AN  
ALARM CONTROL PANEL OR MANY OTHER TYPES OF  
EXTERNAL DEVICES.  
CH5  
TERMINAL  
BLOCK  
GND  
2. ALL GND TERMINALS ARE COMMON GROUND AND  
CONNECTED TOGETHER.  
CH4  
TO XR-16  
CH3  
3. ALL OUTPUTS CAN BE PROGRAMMED FOR NORMALLY  
OPEN OR NORMALLY CLOSED OPERATION. EACH  
OUTPUT RETURNS TO ANY COM TERMINAL.  
OUTPUT  
OPTION  
JUMPER  
CH2  
RELAY  
OPTION  
JUMPER  
MOUNT ANTENNAS AS FAR AS POSSIBLE FROM  
COMPUTERS TO MINIMIZE INTERFERENCE  
GENERATED BY THE COMPUTER  
WIRING  
KNOCKOUTS  
CH1  
4. EACH SOLID STATE OUTPUT CAN SWITCH UP TO  
100 mA @ 24 VDC MAXIMUM.  
 

Krown Manufacturing Personal Computer VTouch TTY User Manual
LG Electronics Range LDE3031ST User Manual
Lightolier Indoor Furnishings 1100IC User Manual
LST Smoke Alarm 5351TE User Manual
Makita Impact Driver BTWI50SA User Manual
Manhattan Computer Products Computer Drive 160766 User Manual
Marshall Amplification Musical Instrument Amplifier B 150 User Manual
Master Appliance Welder GT 70 User Manual
Maxtor DVR CDR 04S User Manual
Microsoft Computer Hardware P2289A User Manual